Server Environment Monitoring
Home / Products / Data Center Infrastructure Management (DCIM) Solution / Envrionment Monitoring Solution (EMS) / EMS for Middle Data Center / Server Environment Monitoring
  • SitemateII

  • SitemateII

  • SitemateII

  • SitemateII

  • SitemateII

Server Environment Monitoring

 

Server Environment Monitoring for Middle Data Center

Server environment monitoring also known as: Remote Environmental Monitoring System, Monitoring Server Room, Data Center Monitoring, Computer Room, Network Cabinet, Temperature Sensor, Remote Power Reboot, Network Alarm Thermometer, Server Room Monitoring.
Environmental threats in a server room are far more damaging than hardware or software issues. If your server room overheats or floods, redundant hardware, backup tapes, UPS battery arrays, generators, and other fault tolerance measures can all fail.

Server environment monitoring products enable you to actively keep track of the problems in your shelf, server room, information centre or anywhere else you require to safeguard essential possessions. The problems kept an eye on consist of severe temperatures, humidity, power spikes and surges, water leaks, smoke and chemical materials. With appropriate environmental monitoring, you look out to any type of problem that might have a negative impact on your mission-critical tools. These datacenter remote monitoring can likewise notify you to prospective damage from human error, hacking or spying fingers.

Overview

Server environment monitoring is specially developed and researched for small data center, it is based on IP network technology, supports UPS monitoring and server environment monitoring detection (temperature, humidity, smoke, leakage, motion, door contact, gas, etc) in one host. SitemateII provides fast interface visiting and user settings via web browser, once an abnormal alarm happens, it will rapidly give alarm notifications with email, SMS, sound light, etc, for a real sense to guarantee 7*24 hours unattended data center.

What is Server Environmental Monitoring?


Environmental monitoring products enable you to proactively monitor conditions in racks, server rooms, data centers, or anywhere else you need to protect critical assets. Conditions monitored include temperature extremes, humidity, power spikes and surges, water leaks, smoke, and chemical materials. With proper environmental monitoring, you will be alerted to any conditions that could adversely affect your mission-critical equipment. They can also alert you to potential damage caused by human error, hacking, or prying fingers.

Server room environmental monitoring systems consist of three main elements: a base unit or hub, probes or sensors, and network connectivity and integration. Hubs may contain one or more built-in sensors, as well as ports for connecting external probes. They also include an Ethernet port and have software for remote configuration and mapping. The software can also be used with existing network management software, such as SNMP systems.

Server environment monitoring

What does a server environmental monitoring system provide?

Data Measurement


Server room environmental monitoring devices display values measured by additional probes, such as temperature, humidity, airflow, dry contact status, door open/close, motion detectors and other sensors.


Data collection and plotting


Measured values are regularly stored in internal memory or external storage media and displayed as graphs.

Alarms and notifications


When a measured value exceeds a predefined threshold, it triggers an alarm: flashing LED on the front panel, audible alarm, SNMP trap, e-mail, SMS, etc. The environmental monitoring device can also activate external alarm systems, such as sirens or strobe lights.

Protect your infrastructure


Data center management needs to address more than just network issues. Infrastructure is the lifeblood of servers and network equipment. Air conditioning systems, UPS systems and backup generators need to operate at peak efficiency to ensure uninterrupted operation. When a $12 fan dies, the best software and technology in the world can't stop an entire infrastructure from collapsing. The remote monitoring system will.

Scalable system can monitor TCP/IP devices


The sitemateII consists of a main "host" unit and supports up to 31 expansion "node" devices. Each host and node has inputs from up to eight environmental sensors. The system also monitors any TCP/IP address device via ping and port availability. Each host or node can monitor up to 64 TCP/IP addresses on your network over an Ethernet connection.

If a server or service stops responding, the sitemateII immediately notifies the appropriate personnel using pre-programmed instructions. The TCP/IP alerting feature is ideal for monitoring routers, web servers, email servers, DNS servers, database servers, and gateways. This means you know when your website or email server is down before your clients or supervisors.

Send alerts through any channel


The system can send alert messages over the network via email or text message, phone line with real voice messages, or Simple Network Management Protocol (SNMP) traps. Using multiple channels allows alert messages to pass through even if the network is down. The system can even make traditional voice calls in the event of an alarm. You can customize the alert function to:

Contact different people based on the type of problem
Dial a different number or send a text message based on the time of day

Types of Server Room Environmental Monitoring


Server room environmental monitoring can include the monitoring of temperature, humidity, fluids, leaks, smoke, fire and other environmental parameters to ensure maximum reliability while reducing cooling costs and enabling greener IT. such activities help protect mission-critical equipment from failure and prevent performance degradation, intermittent failures, overall equipment failure and data loss.

Server Room Temperature Monitoring


Server room temperature monitoring is an automated process that alerts IT administrators when server room temperatures rise above a certain level. Ensuring that server performance is not disrupted by high room temperatures is a critical task.

Server room humidity monitoring


Most electronic components are designed to operate within a specific range of humidity. High humidity environments can cause disk drives to fail, leading to data loss and downtime, while low humidity environments increase the risk of electrostatic discharge (ESD), which can lead to immediate and catastrophic failure of electronic components.

Server room motion detection


Many server rooms are left unattended after hours or even during the day. Other employees may inadvertently damage the server room by opening the door. Installing motion detectors is a simple and affordable way for IT to stay informed and alerted of all activity in the server room.

Server Room Smoke Detection


Additional smoke detectors in the server room will ensure that IT personnel are notified as often as possible in the event of a fire. This allows those responsible to begin disaster recovery procedures as early as possible, thus minimizing overall downtime.

Server Room Camera Monitoring


Closed circuit television cameras are a great way to provide security for server rooms. Not only do they provide video footage of specific events, such as door openings and motion detection, they can also act as a visual deterrent to criminals. Clear, sharp images can be sent to IT staff anywhere via email, FTP, MMS, or streamed directly to cell phones.

Benefits of Server Environment Monitoring


Reduce downtime and improve equipment reliability


When things go wrong, you're the first to know. Minimize downtime by receiving alerts about conditions that cause damage to servers and other network equipment.

Reduce operational costs


Server environment monitoring devices can help you reduce replacement equipment costs and reallocate your workforce more efficiently.

Improve employee satisfaction


Built-in notification features such as email, SMS and SNMP traps enable employees to better manage their work.

Remote Server Environment Monitoring and network distribution facilities from:

Abnormal server temperature
power fluctuation
humidity change
Unauthorized access and break-in

Features of Server Environment Monitoring


With Server Environment Monitoring hubs and sensors, you can monitor a variety of environmental conditions, including temperature, humidity, airflow, smoke, security, and voltage. Installation is quick and easy. Connect hubs to your network, connect sensors, and you can remotely view the status of server rooms, data centers, and other facilities. Check for temperature, humidity and liquids; understand when server cabinet doors are open or closed and if the cabinet is overheating, and monitor assets and infrastructure from anywhere in the world.
Data Measurement and Reporting
Server Environment Monitoring displays values ​​measured by connected sensors. Measurements are periodically stored in the hub's internal memory or external storage medium and displayed as a graph.
Alerts and Notifications
Users can define warning and critical alert states and notification actions, including SNMP traps, email, SMS, alerters, and more. When the measurement exceeds the threshold, it triggers an alarm condition.
Easy to set up and manage
The Server Environment Monitoring hub works out of the box. Plug the sensors into the hub's RJ-45 port, and they automatically configure and come online, ready to report any status changes.
Web-based management interface
The easy-to-use Java™-based Server Environment Monitoring enables you to access the AlertWerks hub over any IP network, even the Internet.
Extensible Platform
Server Environment Monitoring hubs can be daisy-chained to expansion hubs, increasing the total number of sensors to over 500

Product Function

Support advantage encryption protocol such as HTTP, HTTPS, SSL, SSH, SNMPV1\V2c\V3;

Support telnet, supper terminal, WEB page configuration;

Compatible with multi-brand and multi-type of UPS;

Support to add on 20 pieces of Temp&Humid sensors via RS422/RS485 ports;

With 16 digital input terminals, support to add on dry contact type detectors;

With 5 digital output terminals, support to add on relay output control;

Support 8 analog input signal detect;

Support SNMP trap,E-mail alarm notification;

Support IPV4/IPV6;

Built-in optional GSM Modem, support SMS query or alarm notification;

Support scheduled task(regular self-testing, switch on/off);

Support history events and data record storage;

Comprehensive event handle( including event record and notification);

Comprehensive managing function( data logs, SNTP and task schedule);

Available to work with centralized software.

 

Ports Introduction

 

Server environment monitoring

 

Server environment monitoring

 

Server environment monitoring

 

14/17: RS422/RS485
(connect Temp&Humid sensor/general air condition infrared component).
15: Ethernet port
16: RS232 serial port
(connect UPS)
18: Digit output terminals
(connect relay output control)
19: Analog input terminals
20: Digit input terminals(connect dry contact type sensors)

 

 

Dimension

 

Server environment monitoring

 

Monitoring Interface

 

SitemateII

 

Technical Parameters
CPU 32-bit ARM926EJ-S core 300 MHz high speed processor(CPU)
RAM 64Mbyte SDRAM Flash ROM 128M byte and Flash
Network Interface 10/100Mbps high speed Ethernet self adaptive
Device Ports 1 RS232 asynchronous serial port;
1 RS422/485 add on port
16 Digit input terminals (0-5V TTL level);
8 Analog input terminals (0 ~ 5V linear level);
5 Digit output terminals (12VDC / 1A).
Browser Support Internet Explore, Netscape or compatible browsers.
SNMP MIB Support MIBII (RFC1213, RFC1315, RFC1316)RFC1628, PPC MIB
Network Protocol TCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP, ICMP, PPP,etc.
LED Indicators PW, M-PW, RUN, DEV, PPP, IPP, WEBS, SNMP, EXT, MODEM, LAN 10/ 1 00M Link/Active
Input Power 220-240V
Frequency 50Hz Power Consumption ≤ 12W
Operating Environment Temperature:0℃~70℃ Humidity:10~85% Software Upgrade Network upgrade
Other Configuration Real time system clock synchronization
Languages Chinese/English, support OEM other languages.
System Security Provided filtering mechanism based on IP , and system operation, control
and management of the user ID and password protection.
Safety Certificate CE, FCC

 

Accessories
SN Name M.N Function Connection
1 Temp&Humid
Sensor
RC77015
OLED Display
Detect data center indoor temperature and humidity parameters,every 20M² need to install 1pc RS422
RC77012
Digital Type
2 AirCon Infrared Component RC77404 Remotely control air condition on-off,with auto reboot when AC recover RS422
3 Smoke Sensor RC77146 Detect indoor data center monitor status, every 20 M²-30M² need to install 1pc DI (terminals)
4 Infrared Sensor RC77147 Detect data center intrusion, motion status DI (terminals)
5 Door contact RC77424 Detect door or window on/off status DI (terminals)
6 Switching Value
Transmitter
RC77754 Detect on-off status of air condition/ new fan DI (terminals)
7 Sound Light Sensor RC77412 Give sound light alarm notification DI (terminals)
8 Dust Sensor / Detect dust capacity Analog
9 Flammable Gas Sensor / Detect flammable gas Analog
10 Water Leakage
Sensor
RC77106
(Non-Locating)
Detect data center water leakage status, work with water leakage cable, cable (5/10/15/20/30meter)optional, support length custom DI(terminals)

 

If you are interested in our products, please contact us.

Related Products
SiteProII Modular data center solution
NemateIII EXT NemateIII EXT
MobilemateII SMS alarm system for server room